Automation for pellet boilers
MASTER 530 Boiler temperature regulator with feeder
The indicated price is valid ordering till 31.01.2026.
Please contact us on +371 28339922 to check if the item is in stock before making a purchase. Just because the indication is available does not guarantee that the item is available immediately.
The MASTER 530 regulator is intended for regulating the operation of a boiler with automatic fuel supply, a central heating pump, and a hot water pump. and the P3 pump, which can act as: circulation pump, floor pump, backflow protection pump or circulation pump 2, in central heating systems.
The regulator has the following functions:
maintaining the set temperature of the boiler by controlling the feed blowing and operation
the possibility of operating the boiler with an emergency grid
smooth fan operation and adjustable power
programmable boiler blowdown
adjustable extinguishing time and automatic shutdown of the control when there is no fuel
operation control of the central heating circulation pump
Hot water priority can be enabled or disabled
control of the hot water heater filling pump depending on the required temperature
additional pump control that can act as: circulation pump, floor pump, backflow protection pump or circulation pump 2
the ability to operate the boiler and hot water pump according to one of several weekly programs
protection of the hot water heater against the growth of legionella bacteria
COMFORT SYSTEM function that protects the pump against scale formation
protection system - thermal fuse
system protection function against boiler freezing and overheating
signals damage to the temperature sensors
adjustable display brightness - increased for the time of changing settings
possibility to connect remote control with sound alarm function
A DK Logic room thermostat can be connected
The range of measured temperatures is from -9 ° C to + 120 ° C
Temperature setting range for the boiler from + 40°C to + 85°C
Hot water heater temperature setting range from + 40 ° C to + 70 ° C
Central heating pump temperature setting range from +30 °C to +70 °C
Smooth fan start yes
Adjustable maximum fan power 40% - 100%
Fan hysteresis (difference on - off) from 1 °C to 9 °C
Blowout adjustment (possibility to completely turn off blowout) operation: 0 - 90 seconds pause: 5 - 240 minutes
Hot water pump hysteresis (difference on - off) from 2 °C to 9 °C
Permissible output load fan: 100 W / 230 V feeder: 200 W / 230 V central heating pump: 100 W / 230 V hot water pump: 100 W / 230 V P3 pump: 100 W / 230 V
Adjustable boiler extinguishing time 0 - 45 minutes
Nominal supply voltage ~ 230 V, 50 Hz
Electrical protection 2 x 5 A
Relative humidity < 95%
Housing protection degree IP20
Ambient temperature from 0 °C to + 40 °C