Automation for pellet boilers

MASTER 530 Boiler temperature regulator with feeder

ID: 1961
code: 501351
barcode: 501351
in stock
0.00 €
24000
without VAT 198.35 €
inbank3 parts = 80.00
 

    Price includes VAT 21%.
    The indicated price is valid ordering till 31.01.2026.
    Please contact us on +371 28339922 to check if the item is in stock before making a purchase. Just because the indication is available does not guarantee that the item is available immediately.

    The MASTER 530 regulator is intended for regulating the operation of a boiler with automatic fuel supply, a central heating pump, and a hot water pump. and the P3 pump, which can act as: circulation pump, floor pump, backflow protection pump or circulation pump 2, in central heating systems.

    The regulator has the following functions:

    maintaining the set temperature of the boiler by controlling the feed blowing and operation
    the possibility of operating the boiler with an emergency grid
    smooth fan operation and adjustable power
    programmable boiler blowdown
    adjustable extinguishing time and automatic shutdown of the control when there is no fuel
    operation control of the central heating circulation pump
    Hot water priority can be enabled or disabled
    control of the hot water heater filling pump depending on the required temperature
    additional pump control that can act as: circulation pump, floor pump, backflow protection pump or circulation pump 2
    the ability to operate the boiler and hot water pump according to one of several weekly programs
    protection of the hot water heater against the growth of legionella bacteria
    COMFORT SYSTEM function that protects the pump against scale formation
    protection system - thermal fuse
    system protection function against boiler freezing and overheating
    signals damage to the temperature sensors
    adjustable display brightness - increased for the time of changing settings
    possibility to connect remote control with sound alarm function
    A DK Logic room thermostat can be connected

    The range of measured temperatures is from -9 ° C to + 120 ° C
    Temperature setting range for the boiler from + 40°C to + 85°C
    Hot water heater temperature setting range from + 40 ° C to + 70 ° C
    Central heating pump temperature setting range from +30 °C to +70 °C
    Smooth fan start yes
    Adjustable maximum fan power 40% - 100%
    Fan hysteresis (difference on - off) from 1 °C to 9 °C
    Blowout adjustment (possibility to completely turn off blowout) operation: 0 - 90 seconds pause: 5 - 240 minutes
    Hot water pump hysteresis (difference on - off) from 2 °C to 9 °C
    Permissible output load fan: 100 W / 230 V feeder: 200 W / 230 V central heating pump: 100 W / 230 V hot water pump: 100 W / 230 V P3 pump: 100 W / 230 V
    Adjustable boiler extinguishing time 0 - 45 minutes
    Nominal supply voltage ~ 230 V, 50 Hz
    Electrical protection 2 x 5 A
    Relative humidity < 95%
    Housing protection degree IP20
    Ambient temperature from 0 °C to + 40 °C