Heating automation

Regulus Heating system piping kit BIO 55 MIX W-PWM 1F TRS6

ID: 3743
code: 17499
barcode: 8595222671135
manufacturer: Regulus
in stock
0.00 €
168080
without VAT 1389.09 €
inbank3 parts = 560.27
 

    Price includes VAT 21%.
    The indicated price is valid ordering till 31.01.2026.
    Please contact us on +371 28339922 to check if the item is in stock before making a purchase. Just because the indication is available does not guarantee that the item is available immediately.

    Heating system piping kit BIO 55 MIX W-PWM 1F TRS6 

    • Insulated Load Unit with a controller, actuated 3-way mixing valve (Kvs = 6.3 m³/h), 2 pumps, TSV3B 55 °C load valve, ball valves, drain valves, a safety valve and thermometers.
    • The Unit is intended for heating systems with a solid fuel boiler and a thermal store, permitting DHW heating. Heating system water is mixed in a 3-way mixing valve with an electric actuator, while the return water temperature to the boiler is maintained at a minimum of 55°C by a load valve. Boiler heat surplus is stored in a thermal store and automatically used later after the boiler goes out.
    • Includes complete hydraulic and electrical connections for the installation of a heating system with a solid fuel boiler. The load unit features a complete electrical installation and is equipped with a power cord and plug.
    • All that is required is to connect the boiler, the heating system, and the thermal store or stores (depending on the selected hydraulic variant), install the sensors, and plug the load unit into a wall socket.
    • Then, using the setup wizard, select the appropriate hydraulic variant in the controller and set the remaining required parameters.
    • The basic connection diagram can be expanded with optional accessories.
    • Connection: 1"

    Technical Data

    Working parameters:
    • Fluid working temperature: 5–95 °C
    • Max. working pressure: 6 bar
    Min. working pressure: 0.5 bar
    • Ambient temperature: 5–40 °C
    • Max. relative humidity: 80 %, non-condensing
    • Max. temperature of sheath sensors: 95 °C
    • Min. return water temperature to boiler from load valve:
      - 55 °C – code 17499
      - 65 °C – code 21255
      - 70 °C – code 21259
    • Mixing valve actuator run time: 120 s
    Max. boiler output at flow 1.7 m³/h: 40 kW (Δt 20 °C) / 20 kW (Δt 10 °C)
    • Max. heating system output at flow 1.7 m³/h: 40 kW (Δt 20 °C) / 20 kW (Δt 10 °C)
    • Insulation material: EPP RG 60 g/l
     Overall dimensions (H x W x D): 640 x 350 x 231 mm
    • Working fluid: Water, antifreeze heat-transfer fluid for heating systems
     Installation: Vertically on a wall using the installation kit

    Electric data:
    • Power supply: 230 V, 50 Hz (power cord)
    • Max. power input: 155 W (basic connection, no accessories)
     IP rating: IP 20

    Brochure

    Data sheet

    Installation

    Pump installation