Connecting elements and automation for solar systems
Thermostat AVANSA 110 S for circulation pump of solar collector
The indicated price is valid ordering till 01.02.2026.
Please contact us on +371 28339922 to check if the item is in stock before making a purchase. Just because the indication is available does not guarantee that the item is available immediately.
AVANSA 110 S, thermostat for solar collector pumps
The AVANSA 110-S thermostat is designed to control the solar collector pump and the circulation pump. The collector pump operates based on the temperature difference. The pump is switched on when the collector temperature exceeds the reservoir temperature by a user-set hysteresis. The pump switching off depends on the set hysteresis of the pump switching on. The switch-off hysteresis is always 10 °C lower than the switch-on hysteresis. When you set the on hysteresis to 20 °C, the off hysteresis is automatically set to 10 °C. If the hysteresis is set to 10 °C, the pump operates until the collector and reservoir temperatures are equal or until the reservoir temperature set point is reached. The circulator turns on when the reservoir temperature exceeds the user set circulator on temperature and operates until the reservoir temperature falls below the set value.
Technical data:
- Supply voltage: 230V 50Hz ±10%
- Ambient Temperature: -10 ... +50°C
- Switching current: 6A
- Temperature measurement range: 0 ... 150 °C
- Temperature setting range: DHW 20 .... 80 °C
- Hysteresis adjustable reservoir: 10 .... 30 °C
- Maximum sensor temperature: -10 ... 150 °C
- Sensor length: tank temperature sensor - 3 m,
boiler temperature sensor - 1 x 1.2 m